Home> Products> Intelligent hydrology> Dam safety monitoring>Osmotic pressure monitoring station
Osmotic pressure monitoring station

Osmotic pressure monitoring station

Model:FT-SY1
Brand:fengtu
Osmotic pressure monitoring station is mainly used for real-time automatic monitoring of subsurface osmotic pressure in soil landslide, and also for long-term monitoring of water level changes in reservoirs, rivers, lakes and so on....

The seepage pressure monitoring stationis also called the underground seepage pressure monitoring system and the integrated pore water pressure monitoring station. The seepage pressure monitoring station mainly conducts real-time automated monitoring of underground seepage pressure in soil landslides. It is also used for long-term monitoring of water levels in reservoirs, rivers, lakes, etc. amount of change. The FT-SY1 osmotic pressure monitoring station is a hydrological instrument used for water level and water temperature measurement. It is developed through years of accumulation of production technology and using advanced mixed signal processing technology. It overcomes the shortcomings of traditional analog circuit modules and can achieve Full-scale digital linear correction, full-temperature zone digital temperature error compensation; compensation parameters are stored in non-volatile memory, and multiple safety protection mechanisms avoid the product being unusable due to loss of calibration parameters; the circuit module is equipped with power monitoring and gatekeeping The dog monitoring function and the input-type structure are all stainless steel sealed, which greatly improves the reliability of the product.


Features of FT-SY1 Osmotic Pressure Monitoring Station:

l High stability type: high quality and high stability pressure sensing element

l High accuracy: water level accuracy 0.1%FS, resolution 1mm; temperature accuracy ±0.5°C, resolution 0.01°C.

l Low power consumption: intelligent power management design, collection power consumption 3-4MA

l Full-featured: water level, water temperature, water pressure and other factors can be monitored in real time at the same time

l Barometric pressure compensation: using atmospheric pressure direct measurement compensation method (absolute pressure optional)

l Signal standard: RS485 interface MODBUS-RTU standard communication protocol

l Protection level: all stainless steel sealed structure, IP68 protection

l Temperature compensation: full-scale digital calibration, full-temperature zone temperature error compensation

l Electrical characteristics of the sensor: It has over-voltage protection, surge voltage protection and power supply polarity reverse protection to avoid electrical damage caused by operating errors.


Osmotic pressure monitoring station application fields

l Monitoring of groundwater level and temperature data

l Dam safety seepage pressure and liquid level monitoring

l Real-time monitoring of water levels in reservoirs and dams

l Lake and surface runoff water level monitoring

l Unattended hydrological monitoring site

l Real-time monitoring of liquid level in the tank

l On-site liquid level monitoring of industrial control systems


Basic specifications of osmotic pressure monitoring station

Piezoresistive osmometer (piezoresistive pore water pressure meter)

Dimensions

φ26mm length 134mm

Basic specifications of osmotic pressure monitoring station


Basic performance parameters of osmotic pressure monitoring station

Parameter item illustrate
Main performance indicators Sensitive components Piezoresistive silicon
Measuring range 0~10m H₂O
Water level accuracy 0.1%FS/0.25%FS/0.5%FS
water level resolution 1mm
stability 0.1%FS/year0.25%FS/year0.5%FS/year
overload 2XF·S
Temperature accuracy ±0.5℃
Temperature resolution 0.01℃
Electrical characteristics Temperature compensation range 0~50℃
Operating temperature -10~80℃
Supply voltage DC5~30V (typical 24V)
Power protection Anti-reverse connection, over-voltage protection
output method RS485 digital signal/MODBUS-RTU protocol 128 transmitter nodes
Structural properties Shell material 316L stainless steel
Measuring medium fluid medium
Cable material Polyurethane or PVC
Cable specifications Φ7.6mm gas shielded double steel wire cable,
Environmental characteristics Protection level IP68
weight Approximately 250 grams (excluding cables)
Environmental vibration: Withstand the vibration test specified in GB/T9359
free fall Withstand the drop test specified in GB/T9359
electromagnetic environment Comply with GB/T17626.8 level 3
mean time between failures Not less than 30000h
  • Previous:没有了!
  • Next:没有了!
  • Hello, my friend!
    What kind of support do you need? Our products is sure to satisfy you.
    *Name
    *Email
    Phone
    Country
    *Message
    Baidu
    map