Home> Products> Smart water quality> Online Water Quality Analyzer>Online Residual Chlorine Analyzer
Online Residual Chlorine Analyzer

Online Residual Chlorine Analyzer

Model:FT-ZS4
Brand:fengtu
Online Residual Chlorine Analyzer applies to water quality monitoring of tap water pipe network, residual chlorine and PH monitoring of peripheral water and tank secondary water supply....

1.Online Residual Chlorine AnalyzerProduct Introduction

Online Residual Chlorine Analyzer applies to water quality monitoring of tap water pipe network, residual chlorine and PH monitoring of peripheral water and tank secondary water supply.ZS4 Online Residual Chlorine Analyzer is an instrument that can monitor residual chlorine and water quality pH online. It integrates residual chlorine, pH sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.

2. Application fields of Online Residual Chlorine Analyzer

Online Residual Chlorine Analyzer is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:

1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.

2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.

3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.

4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.

5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.

6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.

7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.

3. Technical Features of Online Residual Chlorine Analyzer

1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.

2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.

3. Scalability: Various sensors can be freely combined.

4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.

5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.

6. Compact structure: can be installed in small places.

7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.

4. Technical Parameters of Online Residual Chlorine Analyzer

Display Output 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight
power supply DC power supply: DC12V
Power consumption The power consumption of the instrument is about 12V/1W
Sound Output buzzer
Communication Protocol Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support
Main Materials ABS+PC material
Storage temperature -20 to 70°C
Operating temperature -10 to 50°C
Protection level IP65
size 175mm*140mm*49mm(length×width×height)
weight About 0.5KG

5. Online Residual Chlorine Analyzer Sensor Configuration (Optional)

Serial number name Measuring range principle Measurement accuracy Configuration Remark
1 temperature 0~50℃ High-precision digital sensor ±0.3℃

2 pH 0~14 (ph) Electrochemistry (Salt Bridge) ± 0.1PH
3 ORP -1500mv~1500mv Electrochemistry (Salt Bridge) ± 6mv

4 Conductivity 0~5000uS/cm Contact electrode method ± 1.5%

5 Turbidity 0~40NTU (low turbidity) Scattered light method ± 1%
Optional
0~1000NTU (medium turbidity) Scattered light method ± 1%
0~3000NTU (high turbidity) Scattered light method ± 1%
6 Dissolved oxygen 0~20mg/L Fluorescence lifetime method ± 2%

7 Ammonia nitrogen 0~100mg/l Ion Selective Electrode Method ±1mg

8 Suspended Matter 0~2000mg/L Scattered light method ±5% (depending on sludge homogeneity)

9 Residual chlorine 0~5.00 mg/L Ion Selective Electrode Method ±5% of reading
10 Chloride ion 0-3500.0mg/L Ion Selective Electrode Method ±5%

11 Total hardness 0~1000.0mg/L Ion Selective Electrode Method ±10% of reading

12 cod 0~500mg/L UV254 absorption method ±5%
COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W
13 Chlorophyll 0~400ug/L Fluorescence method R2>0.999
Hello, my friend!
What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
Phone
Country
*Message
Baidu
map